Division 09 / Section 09 29 00 · Gypsum Board
How to Specify Waterguard
To specify Waterguard simply add the following to your existing 092900 drywall accessories specification then edit for the height of product desired on non-fire-rated walls:
Non-fire-rated walls
Provide <select desired height:1/2” tall Waterguard or 1 3/4” tall Waterguard Plus> extruded PVC, GDW Moisture Guard installed continuously at floor level of all GDW throughout building. (go to: www.Waterguard-USA.com).
1-Hour Rated Walls
Provide UL Rated 1/2” tall Waterguard FS extruded PVC (UL BW-S-0078 / XHHW – R42194), GDW Moisture Guard installed continuously at floor level of all 1-Hour Rated walls. (go to: www.Waterguard-USA.com).
2-Hour Rated Walls
Provide UL Rated 1/2” tall Waterguard FS; extruded PVC (UL BW-S-0078 / XHHW – R42194), GDW Moisture Guard installed continuously at floor level of outer layer of GDW on each side of all 2-Hour Rated walls (go to: www.Waterguard-USA.com).
Note to Specifier
- There is no caulk required at the bottom of wall when using Waterguard FS on 1 and 2-hour rated walls (per UL BW-S-0078 / XHHW-R42194) so consider deleting the requirement for fire caulk at the base of rated walls and perhaps referencing 092900.
- When it comes to Smoke Partitions; Waterguard products have been independently tested and received L-ratings of less than 1 cfm/lf at both ambient and elevated temperatures. Therefore, there is no caulk required at bottom of walls for smoke partitions when using Waterguard products, so consider referencing Waterguard products in section 078400 for bottom of wall treatment in lieu of smoke and sound caulk.
- When it comes to Sound Transmission; Waterguard and Waterguard FS have both been independently tested and determined to maintain STC values of up to STC 71 while Waterguard Plus maintained STC values of up to STC 55 without additional sound caulk at the bottom of walls. Therefore, there is no caulk required at bottom of wall for sound control up to these levels so consider also substituting Waterguard products in section 078400 for bottom of wall treatment in lieu of smoke and sound caulk.
- Because we are a still relatively new to the market; contractors frequently fail to identify Waterguard in the specifications, so we ask that you please call out Waterguard on your standard wall type sheets.
- To see Waterguard being installed—please see the installation video at: www.KeepsDrywallDry.com.
Note to Contractor
- There is no caulk required at the bottom of wall when using Waterguard FS on 1 and 2-hour rated walls (per UL BW-S-0078/XHHW-R42194) so consider substituting Waterguard FS at bottom of walls in lieu of fire caulk.
- When it comes to Smoke Partitions; Waterguard products have been independently tested and received L-ratings of less than 1 cfm/lf at both ambient and elevated temperatures. Therefore, there is no caulk required at bottom of walls for smoke partitions when using Waterguard products, so consider substituting Waterguard products at bottom of walls in lieu of smoke and sound caulk.
- When it comes to Sound Transmission; Waterguard and Waterguard FS have both been independently tested and determined to maintain STC values of up to STC 71 while Waterguard Plus maintained STC values of up to STC 55 without additional sound caulk at the bottom of walls. Therefore, there is no caulk required at bottom of walls for sound control up to these levels, so consider substituting Waterguard products at bottom of wall in lieu of smoke and sound caulk.
- To see Waterguard being installed—please see the installation video at: www.KeepsDrywallDry.com.