Mold prevention starts with moisture control at the drywall edge.

Floor moisture can reach the exposed bottom edge of drywall. Waterguard protects that edge as the board is installed.

Waterguard Blog4 min read
The starting condition

Keep drywall off the floor.

GA-216-2021 §4.6.11 requires at least ¼ inch between gypsum panels and the floor. That gap keeps the gypsum from resting directly on the slab.

Holding the board above the slab leaves its paper-faced edge exposed. The gap still needs the right joint protection and backing for rubber base.

Why the detail matters

Mold control starts with moisture control.

The EPA advises controlling moisture to control mold. Repeated or prolonged wetting can damage paper-faced gypsum and require drying, repair or replacement.

Waterguard places a vinyl profile between the slab and the gypsum edge. It protects the bottom of the board; leaks, flooding and humidity still need to be addressed.

Moisture protection at the slab

Waterguard helps protect the bottom edge of gypsum board from routine moisture exposure at the slab. It does not stop leaks, flooding, condensation, or high indoor humidity.

Installation

Protect the edge while the wall is being built.

Waterguard snaps onto the bottom of the drywall before hanging. It keeps the gypsum off the slab, protects the edge and gives rubber base continuous backing.

The protection is in place as the drywall goes up. Choose Waterguard for non-fire-rated walls, Waterguard FS for fire-rated walls under UL BW-S-0078, or Waterguard Plus for non-fire-rated walls needing the taller profile.

  • Choose the product for the wall’s fire, sound, smoke and moisture requirements.
  • Use Waterguard for non-fire-rated walls.
  • Use Waterguard FS for fire-rated walls that meet UL BW-S-0078.
  • Use Waterguard Plus for non-fire-rated walls needing the taller profile.
  • Follow the building’s procedures for cleaning, leaks and drying.
Choose your product

Choose the right Waterguard for your wall.

½-inch profile · Non-fire-rated

Waterguard

Protects the drywall edge, supports rubber base and provides sound performance up to STC 71.

View Waterguard
1- and 2-hour fire-rated walls · BW-S-0078

Waterguard FS

Pink FS protects 1- and 2-hour joints under UL BW-S-0078 without a separate bottom sealant application. FS also achieves STC up to 71 in separate sound tests.

View Waterguard FS
1¾-inch profile · Non-fire-rated

Waterguard Plus

The taller profile provides over an inch of vertical water protection, rubber-base backing, smoke control and STC up to 55.

View Waterguard Plus

Follow the installation instructions for your product. For fire-rated walls, use Waterguard FS and the complete UL BW-S-0078 system.